F016M42K033.A Anthracite

Caule Floor 2

LED light source included. Integrated 220-240V 50-60 Hz electrical power. Cable suitable for outdoors, 5-m long with Schuko IP44 plug. IP65 backlit pedal dimmer switch on the cable for easy ON/OFF and to adjust the amount of light. 110V version upon request. Integrated dimmer control switch (on the cable) Casambi function on demand.

4W - 324lm - 4000K - CRI> 80 - Beam° 52

Are you a professional and your project needs consulting and support?
An exclusive one-on-one service for our professional clients providing specialist support and advice.
Technical Drawing
Main specifications
EAN
8054793253701
Mounting
Floor
Enviroment
Outdoor wet location
Light source type
LED
LED type
Power LED
Number of heads
1
Power (W)
4
System power (W)
3.5
System flux (lm)
324
Schematic light drawing
Photometric
Lighting type
Direct
Light distribution
Symmetric
CCT (K)
4000
CRI>
80
Beam angle C0-180 (º)
52
Beam angle C90-270 (º)
52
Extreme cut off
No
Electrical
Insulation class
III
Frequency (Hz)
50/60
Main voltage (Vac)
220-240
Driver
Integrated
Dimmable
Yes
Dimming type
Dimmer on board
Dimming interface
Dimmer Integrated
Emergency type
No
Physical
Colour
Anthracite
Trim
No
Orientation
Fixed
Net weight (kg)
11.98
IP
65
Dynamic load (kg)
No
CE
IECEE-CB
EAC
USA
65
IK04 - 0.50 Joule
IK04 - 0.50 Joule
65
Notes

We recommend using a connection system with a degree of protection greater than or equal to the degree of protection of the luminaire.
During the installation and the maintenance of the fixtures it is important to be careful and avoid damages on the paint coating.
Damages on the coating exposed to outdoor conditions or water, could cause corrosion.
Chemical substances affect the anticorrosion covering protection.
For LED fixtures, there is evidence that most of the damages are connected to electrical effects related to the insulations, which cause destructive electrical discharges
These effects are frequently caused by:
• over voltage coming from the mains’ network where fixture is connected.
• electrostatic discharge (ESD) coming from the environment.
The use of a protective device against the overvoltage on the electrical installation is warmly suggest this helps to reduce the intensity of some of these phenomenon and prevent irreversible damages. The selection of the type of device to be used must be adjust on the electrical plant.

Ecodesign and Energy Labelling

REPLACEABLE2 Replaceable (LED only) light source by a professional

PWRSUPRPL2 Replaceable control gear by a professional